MD-IBP2 NIBP Module
Meditech NIBP Pump low noise ,low energy consumption,also it environmental,the detail information are as follow: more Details: Air pump fore Blood pressure
MD-IBP2 Digital NIBP module
Small in size, simple, excellent reliability and ease of installation clinical monitoring of the accuracy;
Excellent reliability and accuracy of clinical monitoring
Small in size, simple, excellent reliability and ease of installation clinical monitoring of the accuracy;
Excellent reliability and accuracy of clinical monitoring
Meditech NIBP Pump low noise ,low energy consumption,also it environmental,the detail information are as follow: more Details: Air pump fore Blood pressure
MD-IBP2 Digital NIBP module
Small in size, simple, excellent reliability and ease of installation clinical monitoring of the accuracy;
Excellent reliability and accuracy of clinical monitoring
Small in size, simple, excellent reliability and ease of installation clinical monitoring of the accuracy;
Excellent reliability and accuracy of clinical monitoring
Meditech NIBP Pump low noise ,low energy consumption,also it environmental,the detail information are as follow: more Details: Air pump fore Blood pressure
The latest digital signal processing technology to achieve anti-noise and software algorithms anti-interference by moving arm;
Capable of accomplishing all NIBP measurement items;
Comply with EC safety design;
Comply with all NIBP standard of ANSI/AAMI;
Applies to adults, children and Newborn;
5V/12V single power supply to avoid interference with the digital circuit by the pump;
Fully compatible with the protocol of CAS Non-invasive blood pressure module (NIBP)
MD-IBP2 is a Small Board
NIBP Pump:
1. folw>1.8L/MIN
2. pressure>500 mmHg
3. life>50000times
4. inflation time<10s in 500CC 5.noise<52dB
Measuring range |
Adult: 30 to 255 mmHg systolic blood pressure An average of 20 to 235 mmHg pressure 15 to 220 mmHg diastolic blood pressure Pulse rate of 30 to 240 times / min Newborn: 30 to 135 mmHg systolic blood pressure An average of 20 to 125 mmHg pressure 15 to 110 mmHg diastolic blood pressure Pulse Rate of 40 to 240 times / min |
Measurement time |
Adults: up to more than 120 seconds; Newborn: up to more than 90 seconds; |
Restriction on software over-voltage |
Adult: Less than 290mmHg; Newborns: no more than 145mmHg; |
Protection on hardware over-voltage |
Adult: 300 ±10 mmHg; Newborn: 150 ±4 mmHg; |
Measuring principle | Oscillometry |
Deflation approach | ladder Deflated |
The initial inflation pressure value |
Adult: 150 mmHg; Newborn: 70 mmHg; |
Sensor zero reset | Prior to each measurement |
Resolution | 1 mmHg |
Measurement accuracy |
Maximum average deviation: no more than ± 5 mmHg; maximum standard deviation: less than 8 mmHg; |
Pressure accuracy instructions | ± 3 mmHg |
Leakage | less than 6 mmHg Per minute; |
Electrical performance |
Voltage: 12 VDC (adapt to the corresponding valve), 5 VDC Quiescent current: 80 mA Measurement current: 200 mA inflated current: 600mA |
Environment |
Operating Temperature: 0 to 55 Celsius degrees Storage Temperature: -20 to 65 Celsius degrees Humidity Range: 0 to 95%, non-condenser Operation Altitude: -500 m to 4600 meters Life Span: can operate 100,000 blood pressure measurements |
Size | 12.6 cm x 6.8 cm x 2.8 cm |
Weight: | 180 g |
Options
NIBP Cuff (infant 8 - 14 cm 5/Bag)
NIBP Cuff (infant 8 - 14 cm 5/Bag)
NIBP Cuff (Child 13 - 20 cm 5/Bag)
NIBP Cuff (Small Adult 18 - 26 cm 5/Bag)
NIBP Cuff (Adult 26 - 35 cm 5/Bag)
NIBP Cuff (Adult Long 29 - 38 cm 5/Bag)
NIBP Cuff (Large Adult 32 - 42 cm 5/Bag)
NIBP Cuff (Large Adult Long 35 - 44 cm 5/Bag)
NIBP Cuff (Thigh 42 - 50 cm)
NIBP Tube 150cm
NIBP Tube 150cm
Meditech Equipment Co.,Ltd is part of Meditech Group. Product(s) described may not be licensed or available for sale in all countries. Sonotech, Sonovet, iSonic, FOs2pro, Dolphi, Defi, HeartRec,miniScan,Cardios,SpirOx,iBreath, Meditech and all corresponding design marks are trademarks of Meditech. The symbol indicates the trademark is registered. Patent and Trademark Office and certain other countries. All other names and marks mentioned are the trade names, trademarks or service marks of their respective owners. Please see the Instructions for Use for a complete listing of the indications, contraindications, warnings and precautions.