Blood Pressure SPO2 PR Monitor Echo80

Blood-Pressure-SPO2-PR-Monitor Echo80

 

Echo80 24 hour Automatic Ambulatory Blood Pressure, Blood Oxygen Saturation, Pulse Rate Medical Patient Monitor.

 

Introduction
 

Echo80 is a multifunctional patient monitor, it can monitor SPO2 and NIBP for a long time, and applies to the hospital wards or family daily health care.


Features
Compact and portable, easy to use
With Integrative SpO2 Probe
Double working modes, monitoring function and 24 hours ambulatory NIBP measure function can be flexibly set
NIBP and SpO2 can be monitored for a long time
NIBP and SpO2 data record for large capacity
With friendly user interface, the user can see list menu and review measure results
The device can display low power information, alarm information, error information and time information richly
Parameter alarm function is optional
Patient information can be flexibly set

Case management function. PC software can achieve data review, analysis measure results, seeing trend, printing reports and other functions

Performance

NIBP           
Measure Method: Oscillometry
Measure Mode: The upper arm measure
Measure range: 
ADULT:       SYS: 40mmHg~270mmHg
                 MAP:20mmHg~235mmHg
                 DIA: 10mmHg~215mmHg
PEDIATRIC:  SYS: 40mmHg~200mmHg
                 MAP: 20mmHg~165mmHg
                 DIA: 10mmHg~150mmHg
NEONATAL:  SYS: 40mmHg~135mmHg
                 MAP: 20mmHg~110mmHg
                 DIA: 10mmHg~100mmHg
Automatic measure Interval: 5,10,15,20,30,45,60,90,120 minutes
Resolution: 1mmHg
Accuracy: ±3mmHg
Increasing pressure mode: force pump increases pressure automatically
Reducing pressure mode: self-motion ladder reducing pressure mode

Alarm parameter: SYS / MAP / DIA

SPO2    (Options)   
Measure range: 0%~100% (Resolution:1%) 
Accuracy: 70-100%, ±2%, below 70% unspecified
Error in Weak Filling Condition:
SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%. SpO2 error is ±4%, pulse rate error is ±2 bpm or ±2% (select larger).
Resistance to surrounding light:

The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ±1%.

 

Pulse Rate     (Options)   
Measuring range: 0bpm~250bpm
Resolution: 1bpm
Accuracy: ±2 bpm or ±2% (select larger) 
Display: 2.4" TFT color LCD
Power: DC 3V(Two "AA", 1.5V Alkali Battery)

Product safety type: Type BF applied part (Internally powered, defibrillation-proof)

 

Accessories
Cuff For Adult
Integrative SpO2 Probe
USB Data Line
Disk (PC software) 
Pack

User Manual

Dimensions and Weight
Dimension: 128mm*69mm*36 mm

Weight: <350g

Software Advantage

  • Up to 1000 patient cases can be edited and supervised.
  • The time segment of dealing with the patient’s NIBP data is 48 hours.
  • Connect the device by USB interface.
  • Can upload patient information data collection project and download collection data.
  • Can display scoop-shape trend graph, filling-type trend graph, histogram, pie chart, correlation line graph.
  • Can edit every piece of data, and add annotation to it.

 

  • Can edit basic information,doctor's advice information, NIBP and SpO2 status instruction, current medicine-taken information, etc. 

 

  • Support print preview and report printing.

 

Ambulatory Blood Pressure Monitor PC Software