MD908C
MD908C is a compact Multi-parameter Patient Monitor with 12 inch color TFT display.
It has standard parameters as ECG, NIBP and SPO2, and optional parameters as RESP, 2-TEMP, 2-IBP, ETCO2, Network, Thermal Printer.

Best Solution for OEM 
MD908C is a compact Multi-parameter Patient Monitor with 12 inch color TFT display.
It has standard parameters as ECG, NIBP and SPO2, and optional parameters as RESP, 2-TEMP, 2-IBP, ETCO2, Network, Thermal Printer.

Best Solution for OEM 
Read More
High resolution 12” color TFT display
12 Channel waves.9 Parameters : ECG, Resp, NIBP, SpO2, TEMP,
Light weight, compact and portable
Built-in rechargeable lithium battery 
Unique human voice alarm
Powerful storage: Maximum 720 Hour graphic and tabular trends of all
parameters, up to 10000 NIBP review ,200alarm review ,2Hours of all waveforms
System software can be upgraded through network
Arrhythmia analysis and S-T segment analysis
Suitable for adult, paediatric and neonatal patient




Options 
Invasive Blood Pressure (IBP)
Carbon dioxide (CO2) Module
Thermal Printer
Touch Screen

 
ECG
Lead Mode                    5 Leads ( R L F N C or RA LA LL RL V)
Lead selection              I II III avR avL avF V 
Waveform                       2 ch
Lead mode                    3 Leads ( R L F or RA LA LL)
Lead selection              I II III 
Waveform                      1 ch
Gain                              ′2.5mm/mV ′5.0mm/mV ′10mm/mV ′20mm/mV
HR and Alarm        
Range     
Adult                        15 ~ 300 bpm
Neo/Ped                15 ~ 350 bpm
Accuracy              ±1% or ±1bpm which great
Resolution             1 bpm
Sensitivity             > 200 uV P-P
Differential Input Impedance > 5 MΩ
CMRR
Monitor                    > 105 dB
Operation               > 105 dB
Diagnosis              > 85 dB
Electrode offset potential        ±300mV
Leakage Current                         < 10 uA
baseline Recovery                      < 3 s  After Defi.
ECG Signal Range                      ±8 mV (Vp-p)  
Bandwidth   
Surgery                 1 ~ 15 Hz
Monitor                 0.5 ~ 35 Hz
Diagnostic           0.05 ~ 100 Hz
Calibration Signal                        1 mV (Vp-p)  ±5%  Accuracy
ST Segment Monitoring Range            
Measure and Alarm       -2.0 ~ +2.0 mV
ARR Detecting       
Type                             ASYSTOLE VFIB/VTAC COUPLET BIGEMINY TRIGEMINY R ON T VT>2 PVC TACHY BRADY MISSED BEATS PNP PNC
Alarm                           Available
Review                         Available
 
RESPARATION
Method                                                Impedance between R-F(RA-LL)
Differential Input Impedance         >2.5 MΩ
Measuring Impedance Range:      0.3~5.0Ω
base line Impedance Range:        0 – 2.5 KΩ
Bandwidth                                          0.3 ~ 2.5 Hz
Resp. Rate
Measuring and Alarm Range      Adult              0 ~ 120 rpm
                                                           Neo/Ped         0 ~ 150 rpm
Resolution                    1 rpm
Accuracy                       ±2 rpm
Apean Alarm                10 ~ 40 S
 
NIBP
Method                                      Oscillometric
Mode                                         Manual Auto STAT
Measuring Interval in AUTO Mode 1 2 3 4 5 10 15 30 60 90 120 180 240 480 Min
Measuring Period in STAT Mode   5 Min
Pulse Rate Range                       40 ~ 240 bpm
Alarm Type                      SYS DIA MEAN
Measuring and alarm Range                Adult Mode
SYS             40 ~ 270 mmHg
DIA              10 ~ 215 mmHg
MEAN           20 ~ 235 mmHg
                     Pediatric Mode
SYS             40 ~ 200 mmHg
DIA               10 ~ 150 mmHg
                     MEAN        20 ~ 165 mmHg
                     Neonatal Mode
SYS             40 ~ 135 mmHg
DIA              10 ~ 100 mmHg
MEAN           20 ~ 110 mmHg
Resolution      
Pressure       1mmHg
 
Accuracy Pressure 
Maximum Mean error                     ±5mmHg
Maximum Standard deviation       ±8mmHg
Overpressure Protection
Adult Mode                  297±3 mmHg
Pediatric Mode        240±3 mmHg
Neonatal Mode        147±3 mmHg
 
SpO2
Measuring Range          0 ~ 100 %
Alarm Range                 0 ~ 100 %
Resolution                    1 %
Accuracy                     70% ~ 100%  ±2 %
                                       0%  ~  69% unspecified
Actualization interval      about 1Sec.
Alarm Delay                   10 Sec.
Pulse Rate 
Measuring and Alarm Range 
0~254bpm
Resolution                   1bpm
Accuracy                     ±2bpm
Alarm Delay                 10 Sec.
 
TEMPERATURE 
Channel                                     2
Measuring and Alarm Range        0 ~ 50 °C
Resolution                                  0.1°C
Accuracy                                          ±0.1°C
Actualization interval                   about 1 Sec.
Average Time Constant                < 10 Sec.
 
Options: EtCO2 IBP Recorder
 

Product Features

    High resolution 12” color TFT display
    12 Channel waves.9 Parameters : ECG, Resp, NIBP, SpO2, TEMP,
    Light weight, compact and portable
    Built-in rechargeable lithium battery 
    Unique human voice alarm
    Powerful storage: Maximum 720 Hour graphic and tabular trends of all
    parameters, up to 10000 NIBP review ,200alarm review ,2Hours of all waveforms
    System software can be upgraded through network
    Arrhythmia analysis and S-T segment analysis
    Suitable for adult, paediatric and neonatal patient




    Options 
    Invasive Blood Pressure (IBP)
    Carbon dioxide (CO2) Module
    Thermal Printer
    Touch Screen

Product Specifications

     
    ECG
    Lead Mode                    5 Leads ( R L F N C or RA LA LL RL V)
    Lead selection              I II III avR avL avF V 
    Waveform                       2 ch
    Lead mode                    3 Leads ( R L F or RA LA LL)
    Lead selection              I II III 
    Waveform                      1 ch
    Gain                              ′2.5mm/mV ′5.0mm/mV ′10mm/mV ′20mm/mV
    HR and Alarm        
    Range     
    Adult                        15 ~ 300 bpm
    Neo/Ped                15 ~ 350 bpm
    Accuracy              ±1% or ±1bpm which great
    Resolution             1 bpm
    Sensitivity             > 200 uV P-P
    Differential Input Impedance > 5 MΩ
    CMRR
    Monitor                    > 105 dB
    Operation               > 105 dB
    Diagnosis              > 85 dB
    Electrode offset potential        ±300mV
    Leakage Current                         < 10 uA
    baseline Recovery                      < 3 s  After Defi.
    ECG Signal Range                      ±8 mV (Vp-p)  
    Bandwidth   
    Surgery                 1 ~ 15 Hz
    Monitor                 0.5 ~ 35 Hz
    Diagnostic           0.05 ~ 100 Hz
    Calibration Signal                        1 mV (Vp-p)  ±5%  Accuracy
    ST Segment Monitoring Range            
    Measure and Alarm       -2.0 ~ +2.0 mV
    ARR Detecting       
    Type                             ASYSTOLE VFIB/VTAC COUPLET BIGEMINY TRIGEMINY R ON T VT>2 PVC TACHY BRADY MISSED BEATS PNP PNC
    Alarm                           Available
    Review                         Available
     
    RESPARATION
    Method                                                Impedance between R-F(RA-LL)
    Differential Input Impedance         >2.5 MΩ
    Measuring Impedance Range:      0.3~5.0Ω
    base line Impedance Range:        0 – 2.5 KΩ
    Bandwidth                                          0.3 ~ 2.5 Hz
    Resp. Rate
    Measuring and Alarm Range      Adult              0 ~ 120 rpm
                                                               Neo/Ped         0 ~ 150 rpm
    Resolution                    1 rpm
    Accuracy                       ±2 rpm
    Apean Alarm                10 ~ 40 S
     
    NIBP
    Method                                      Oscillometric
    Mode                                         Manual Auto STAT
    Measuring Interval in AUTO Mode 1 2 3 4 5 10 15 30 60 90 120 180 240 480 Min
    Measuring Period in STAT Mode   5 Min
    Pulse Rate Range                       40 ~ 240 bpm
    Alarm Type                      SYS DIA MEAN
    Measuring and alarm Range                Adult Mode
    SYS             40 ~ 270 mmHg
    DIA              10 ~ 215 mmHg
    MEAN           20 ~ 235 mmHg
                         Pediatric Mode
    SYS             40 ~ 200 mmHg
    DIA               10 ~ 150 mmHg
                         MEAN        20 ~ 165 mmHg
                         Neonatal Mode
    SYS             40 ~ 135 mmHg
    DIA              10 ~ 100 mmHg
    MEAN           20 ~ 110 mmHg
    Resolution      
    Pressure       1mmHg
     
    Accuracy Pressure 
    Maximum Mean error                     ±5mmHg
    Maximum Standard deviation       ±8mmHg
    Overpressure Protection
    Adult Mode                  297±3 mmHg
    Pediatric Mode        240±3 mmHg
    Neonatal Mode        147±3 mmHg
     
    SpO2
    Measuring Range          0 ~ 100 %
    Alarm Range                 0 ~ 100 %
    Resolution                    1 %
    Accuracy                     70% ~ 100%  ±2 %
                                           0%  ~  69% unspecified
    Actualization interval      about 1Sec.
    Alarm Delay                   10 Sec.
    Pulse Rate 
    Measuring and Alarm Range 
    0~254bpm
    Resolution                   1bpm
    Accuracy                     ±2bpm
    Alarm Delay                 10 Sec.
     
    TEMPERATURE 
    Channel                                     2
    Measuring and Alarm Range        0 ~ 50 °C
    Resolution                                  0.1°C
    Accuracy                                          ±0.1°C
    Actualization interval                   about 1 Sec.
    Average Time Constant                < 10 Sec.
     
    Options: EtCO2 IBP Recorder
     