12.1 "screen color LCD display, rotatable screen to 75°   
	Display of the patient data and curve clearly   
	FHR 120 BPM~160 BPM normal range label   
	Manual records fetal movement   
	Sound and color alarm for high and low fetal heart rate   
	Continuous 24-hour real-time monitoring function   
	Continuous 12-hour patient curve and data storage , playback and print   
	With picture freeze function   
	Single, Twins Monitoring optional   
	9 crystal board band pulsed wave transducer  
	Extra-long life, high-resolution built-in thermal recorder   
	Built-in communication port, can be connected with central monitoring system.
	
Options:
Multiparameter Patient Monitor Module
(ECG, SpO2, RESP, PR, NIBP).
            Options:
Multiparameter Patient Monitor Module
(ECG, SpO2, RESP, PR, NIBP).
	Display
Dimensions: 12.1 inch display, folding 75 degree
	 
Dimensions: 12.1 inch display, folding 75 degree
	Content: 
Bed No..............................................
Pregnancy weeks..............................
Age....................................................
Paper speed......................................
Date...................................................
Time...................................................
Volume...............................................
Alarm status.......................................
Transducer connection status............
Recorder status..................................
FHR data and wave..........................
Contraction data and wave...............
Fetal move times and mark...............
Bed No..............................................
Pregnancy weeks..............................
Age....................................................
Paper speed......................................
Date...................................................
Time...................................................
Volume...............................................
Alarm status.......................................
Transducer connection status............
Recorder status..................................
FHR data and wave..........................
Contraction data and wave...............
Fetal move times and mark...............
	Ultrasound probe:
	Nominal Frequency: 1.0 MHz
	Work Frequency: 1.0 MHz±10 %
	Negative peak sound pressure : p_<1 MPa
	Output beam intensity : Iob<20 mW/cm2
	The peak time space peak intensity: Ispta<100 mW/cm2
	The average time space peak intensity: Isata<10 mW/cm2
	FHR Rang: 50 BPM~240 BPM
	Resolution: 1 BPM
	Accuracy : ±2 BPM
	FHR
	Ultrasound Frequency: 2MHz
	Range: 50 ~ 210 bpm
	Resolution: 1bmp
	Accuracy: ±2bmp
	TOCO
	Range: 0 ~ 100%
	Resolution: 1%
	Non-linear Error: <=±8%
	Zero control: Manual
	FETAL MOVEMENT:
	For the manual button (the operation of pregnant women), there will be a mark display in the bottom area of FHR wave display section.
	SPO2 (Options)
	Measurement Range: 0 ~ 100%
	Resolution: 1%
	Accuracy: ±2%(70%~100%, Adult/Pediatric, non-motion)
	±3%(70%~100%, Neonate, non-motion)0% ~ 69% unspecified
	Alarm Range: 0% ~ 100%
	Refreshing Rate: 1s
	Pulse Rate (Options)
	Measurement Range: 25 ~ 250 bpm
	Resolution: 1bpm
	Accuracy: ±3 bpm (non-motion)
	Alarm Range: 25 ~ 250 bmp
	Refreshing Rate: 1s
	ECG (Options)
	Lead mode: 3-lead or 5-lead
	Lead selection: I, II, III, AVR, AVL, AVF, V
	HR range: 15 ~ 300 bpm
	ECG Waveform: 2 channels
	Accuracy: ±2bpm or ±2%, which is greater
	S-T segment detection range: -2.0mv ~ +2.0mv
	Arrhythmia analysis: 13 kinds of arrhythmia
	Alarm Range: 15 ~ 300 bpm
	NIBP (Options)
	Method: Oscillometry
	Mode: Manual/Auto/Continuous
	Measurement Range: 25 ~ 260mmHg
	Auto Measure Interval: 5, 10, 15, 30, 45, 60, 90 minutes
	Resolution: 1mmHg
	Overpressure Protection: 300mmHg
	Alarm range: 25 ~260mmHg
		Print:   
	
		Record Paper two-double type Z
	
		Print Width: 112 mm
	
		Valid Print Width: 104 mm   
	
		Paper output speed: 1 cm/min、2 cm/min、3 cm/min(optional)   
	
		Data Precision: ±5 %(X Roll),±1 %(Y Roll)
	
		Record Content: hospital , bed No. ,name, pregnancy weeks, patient No., paper speed, date,    time , FHR data and wave, Contraction data and wave, Fetal move times and mark etc.
		 
	
		Safety :
	
		Anti-shock types: Facilities I, no internal power supply           
	
		Anti-electric Shock Degree: B    
	
		Working Voltage: AC 100 V~240 V    
	
		Frequency: 50 Hz/60 Hz    P<60 VA    
	
		Fuse: T1.6AL250VDisplay
	
	Options:
	Ultrasound Transducer 
	Physical Characteristics
	 Size: 320 mm (length) × 260 mm (width) × 80 mm (height)    
	 Weight: about 3 kg
	Standard:
Ultrasonic Transducer ..... 1Pcs
TOCO Transducer .......... 1Pcs
Switch Remote ............... 1Pcs
			Abdomen belt  ................. 1Pcs
		Z Thermal Paper     ......... 1PcsGround Cable ................ 1Pcs
Ground Cable ................ 1Pcs
Fuse ............................... 2Pcs
Cleaning Cloth ................ 1Pcs
Options:
ECG Cable (3 Leads)
ECG Alligator Clips (Metal)
SpO2 Cable (Adult)
SpO2 Cable (New born)
			SpO2 Cable (Adult finger clip) 
		
			SpO2 Cable (Child finger clip) 
		
			SpO2 Cable (multi-site Y type)
		
			SpO2 probe (Soft tip)
SpO2 External Cable
	SpO2 External Cable
		NIBP Cuff (Child 13 - 20 cm 5/Bag)
	
		NIBP Cuff (Small Adult 18 - 26 cm 5/Bag)
	
		NIBP Cuff (Adult 26 - 35 cm 5/Bag)
	
		NIBP Cuff (Adult Long 29 - 38 cm 5/Bag)
	
		NIBP Cuff (Large Adult 32 - 42 cm 5/Bag)
	
		NIBP Cuff (Large Adult Long 35 - 44 cm 5/Bag)
	
		NIBP Cuff (Thigh 42 - 50 cm)
NIBP Tube 150cm
	NIBP Tube 150cm
		Paper Role
Thermal printer
Patient Monitor Wall mounts (3 Models)
Patient Monitor Trolley (5 Models)
Thermal printer
Patient Monitor Wall mounts (3 Models)
Patient Monitor Trolley (5 Models)
Product Features
	12.1 "screen color LCD display, rotatable screen to 75°   
	Display of the patient data and curve clearly   
	FHR 120 BPM~160 BPM normal range label   
	Manual records fetal movement   
	Sound and color alarm for high and low fetal heart rate   
	Continuous 24-hour real-time monitoring function   
	Continuous 12-hour patient curve and data storage , playback and print   
	With picture freeze function   
	Single, Twins Monitoring optional   
	9 crystal board band pulsed wave transducer  
	Extra-long life, high-resolution built-in thermal recorder   
	Built-in communication port, can be connected with central monitoring system.
	
Options:
Multiparameter Patient Monitor Module
(ECG, SpO2, RESP, PR, NIBP).
			Options:
Multiparameter Patient Monitor Module
(ECG, SpO2, RESP, PR, NIBP).
 
 







 
                     
                     
                     
                     
					 
		